Home News About Us Contact Us

Refrigerated Air Dryers:

Arctic Star AS Series

Ecostar RD Series

High Inlet Temperature ZDHT Series

 

Back to Dryers & Condensate Treatment

Arctic Star AS Series

Design

Warm saturated compressed air enters an air-to-air heat exchanger where it is cooled by cold dry compressed air passing in the opposite direction. The temperature of this partially cooled air is finally reduced to the required pressure dew point upon entering the refrigerant/air heat exchanger. The resulting condensate is separated by a demister mechanical separator, and discharged by an efficient automatic drain that wastes ZERO compressed air.

Features

Constant air purity to the ISO Standard 1.4.1.
Capillary injection for reliable operation.
Compact full-size heat exchanger to handle overload conditions.
Integrated "slow flow demister" for efficient moisture removal at all operating conditions.
Scroll-refrigerant compressor reduces power consumption. No crankcase heater required and instant start-up.
Modern full-size heat exchanger design results in a low pressure differential and lower cost of operation.
Compact design: a small footprint enables easy installation and full use of the floor space by being 30% smaller & lighter.
Custom engineered packages available upon request.
Environmentally friendly refrigerant: all models use safe R407C which is 30% more efficient than traditional HFC refrigerants.
Zero air loss drains increase energy efficiency.
Cycle control ensures that the dryer will never freeze for reliable operation.

Specification

All models:
Maximum ambient temperature: 122F (50C).
Minimum ambient temperature: 41F (5C).
Maximum inlet temperature: 140F (60C).
Maximum pressure 174 psig.

Type Capacity*, scfm Compressor Power, kW Dimensions, in Connection Weight, lbs Primary Voltages**
AS125 125 0.71 24x31x22 1 " NPT 143 1, 2
AS150 150 0.76 24x31x22 1 " NPT 146 1, 2
AS175 175 1.07 24x31x22 1 " NPT 150 2
AS200 200 1.36 24x31x22 1 " NPT 154 2
AS250 250 1.43 36x40x27 1 " NPT 309 3, 4
AS325 325 1.69 36x40x27 2" NPT 313 3, 4
AS400 400 2.33 36x40x27 2" NPT 317 3, 4
AS500 500 2.34 36x40x27 2" NPT 331 3, 4
AS700 700 2.94 40x59x52 3" NPT 882 3, 4
AS800 800 2.96 40x59x52 3" NPT 926 3, 4
AS1000 1000 4.06 40x59x52 3" NPT 992 4
AS1200 1200 4.23 40x59x52 3" NPT 1014 4
AS1400 1400 6.13 40x59x52 4" ANSI 1036 4
AS1600 1600 7.57 40x59x71 4" ANSI 1212 4
AS1800 1800 7.80 40x59x71 4" ANSI 1223 4
AS2000 2000 7.81 40x59x71 6" ANSI 1290 4
AS2400 2400 9.17 40x59x71 6" ANSI 1301 4
AS3000 3000 11.75 40x59x71 6" ANSI 1455 4

* At ambient temperature 100F (38C), inlet temperature 100F (38C) (relative humidity 60%), working pressure 100 psig.

** 1 = 115V/1Ph/60Hz; 2 = 230V/1Ph/60Hz; 3 = 230V/3Ph/60Hz; 4 = 460V/3Ph/60Hz.

To learn the dryer capacity at other conditions, multiply nominal capacity by the product of correction factors C1 C2 C3:

Ambient temperature 90F
(32C)
100F
(38C)
110F
(43C)
120F
(49C)
122F
(50C)
-
Correction factor C1 1.05 1.00 0.94 0.79 0.71 -
 
Inlet temperature 90F
(32C)
100F
(38C)
110F
(43C)
120F
(49C)
130F
(54C)
140F
(60C)
Correction factor C2 1.22 1.00 0.82 0.68 0.56 0.46
 
Working pressure, psi 50 80 100 125 150 174
Correction factor C3 0.77 0.93 1.00 1.07 1.12 1.15

Please contact us for assistance, more technical details and current prices.

Phone (403) 287-2345 Toll-free 1-(800)-565-2345 Fax (403) 287-1355 E-mail: sincaninc@telus.net