Condensate is the liquid formed from water vapour in the air as a result of a drop in temperature and/or an increase in pressure. This liquid water mixes with atmospheric hydrocarbon contaminants as well as oil carried over from lubricated compressors to form an acidic oily sludge. A 1000 SCFM compressor operating at 100 PSIG, in 20C (68F), 65% RH environment can produce up to 58,000 gallons (219,000 L) of oil contaminated condensate per year.

 

Standard features and benefits

No external power required.

Optional

Remote overflow alarm connection.

Specification

Model Volume,
gal
Dimensions, in. Inlet Conn., in. Outlet Conn., in Oil Conn., in. Weight
(lbs)
Height Width Depth
SL 100 N/V 33 13 12 3/4 3/4 3/4 13
SL 200 20 32 14 18 3/4 3/4 3/4 26
SL 300 33 47 26 20 1 1 1 59
SL 400 49 47 26 26 1 1 1 79
SL 500 94 60 34 28 1 1 1 154
SL 600 128 60 34 39 1 1 1 214

Sizing guidelines

Compressor Type Ecosep Model Oil classification
Class 1
Turbine Oil, cfm
Class 2
Mineral, PAO, TMP & PE oils, cfm
Class 3
Diester, Triester PAG oils, cfm
Reciprocating Compressors SL 100 40 35 30
SL 200 120 100 80
SL 300 435 370 315
SL 400 835 730 620
SL 500 1000 850 725
SL 600 1500 1275 1084
Rotary Screw & Rotary Vane Compressors SL 100 60 50 45
SL 200 165 140 120
SL 300 610 520 440
SL 400 1200 1030 875
SL 500 1610 1370 1165
SL 600 3220 2740 2325

PAO = polyalphaolefins, TMP = trimethylolpropane ester, PE =  pentaerythrityl ester, PAG = polyoxyalkylene glycol.

The above values are not applicable for polyglycol lubricants or ATF (Automatic Transmission Fluid). The sizing guidelines are based upon an ambient inlet temperature to the compressor of 70F (20C) and a relative humidity of 65%. For all other operating conditions use the correction factor tables below to properly size the separator.

Correction factor for ambient temperature at the compressor inlet

Temp. 40F
4C
50F
10C
60F
16C
70F
20C
80F
27C
90F
32C
100F
38C
110F
43C
120F
49C
Factor 2.82 1.96 1.39 1.00 0.73 0.54 0.40 0.31 0.22

Correction factor for relative humidity of the ambient air at the compressor inlet

RH 50% 55% 60% 65% 70% 75% 80% 85% 90% 95% 100%
Factor 1.30 1.18 1.08 1.00 0.93 0.87 0.81 0.76 0.72 0.68 0.65

Please contact us for more details, assistance or current prices.